ГлавнаяУязвимости → CVE-2026-5397
7.8высокая

CVE-2026-5397

Описание

It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that is then executed with administrator privileges. If a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL may be executed by exploiting the product’s behavior of loading missing DLLs from the same directory as the executable during service startup.

CVSS
Балл7.8 — высокая
ВекторCVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H
Источники
https://www.omron.com/global/en/inquiry/data/OMSR-2026-001_en.pdfhttps://www.omron.com/jp/ja/inquiry/data/OMSR-2026-001_ja.pdf